Scope of Application
High-rise residential buildings, refuge rooms
Technology and Performance
1. Applicable Standards: GB 16809-2008 “Fire-resistant Windows” and GB/T 8478-2008 “Aluminum Alloy Doors and Windows.”
2. Fire resistance: Class C, with a fire-resistance integrity of up to 1.0 hour.
3. High-quality 50 and 55 series aluminum alloy profiles are used, with reinforcing steel added inside the profile cavities.
4. Fire-resistance integrity: greater than 1.0 hour; select either insulated fire-rated glass or single-pane fire-rated glass of the corresponding rating.
5. A wide range of window types and specifications: Various window types are available (fixed windows, operable windows), and custom fabrication is also possible according to the specifications and dimensions requested by the customer.
6. Window appearance: Can match the color and shape of ordinary windows, offering a beautiful and elegant look.
Production process
Steel processing → Aluminum processing → Aluminum-steel composite → Punching → Assembly → Detailed fireproofing treatment
Material Selection and Explanation
Aluminum-alloy non-insulated fire-resistant windows feature an outer layer of aluminum alloy extrusions and an inner layer of steel profiles, combining the structural support provided by steel under fire exposure with the aesthetically pleasing appearance of aluminum. Fire-expanding sealing strips are installed at the frame–sash joints and within the profiles, enhancing air tightness, water tightness, wind-pressure resistance, and fire performance—resulting in superior overall performance compared with standard fire-resistant windows available on the market.
Load-bearing structure
Steel liners are inserted into aluminum profiles and joined through a specially designed connection to form a steel frame system that serves as the load-bearing structural support (system fire-rated window).
Technical Specifications
|
Name |
Related parameters |
|
Aluminum alloy window frames |
1.6mm |
|
Aluminum alloy profile window sash |
1.6mm |
|
Steel lining |
1.0mm |
|
Wind Pressure Resistance Performance |
Level 9 |
|
Air-tightness performance |
Level 8 |
|
Watertightness |
Level 4 |
|
Fire resistance |
C1.00 rating: Fire-resistance integrity ≥ 1.00 hour |
|
Thermal insulation performance |
Not lower than Level 4 |
|
Sound insulation performance |
Not lower than Level 2 |
|
Hollow Fire-Resistant Glass |
6mm+9A+6mm |


Keywords
Non-insulated Fire-resistant Aluminum Alloy Window (Series 50)
Contact Us